Send Print
  1. pin-int

Siemens B240

Siemens Series BL Standard Circuit Breaker, Commercial, 120/240 VAC, 40 A, 10 kA Interrupt, 2 Pole, 60 Hz

Siemens Series BL Circuit Breaker, Standard, Commercial, 120/240 VAC, 40 A, 60 Hz, 10 kA Interrupt, Non-Interchangeable, Fixed Thermal Magnetic Trip, 2 Pole, Bolt-On Tab, 8 - 6 AWG Copper, 8 - 4 AWG Aluminum Wire, Load Lug-In/Lug-Out Terminal, Panel Board Mount, 40 deg C, 3.75 Inch L x 1 Inch W x 2.37 Inch D, Includes: Insta Wire

Amperage Rating      :      40 A
Commercial/Residential      :      Commercial
Connection Type      :      Bolt-On Tab
Dimensions      :      3.75 Inch L x 1 Inch W x 2.37 Inch D
Frequency Rating      :      60 Hz
Includes      :      Insta Wire
Interrupt Rating      :      10 kA
Mounting Type      :      Panel Board
Number of Poles      :      2
Series      :      Series BL
Temperature Rating      :      40 deg C
Terminal Type      :      Load Lug-In/Lug-Out
Trip Type      :      Non-Interchangeable, Fixed Thermal Magnetic
Type      :      Standard
Voltage Rating      :      120/240 VAC
Wire Size      :      8 - 6 AWG Copper, 8 - 4 AWG Aluminum

Siemens general application circuit breakers are industrial design thermal magnetic breakers with valuable features for the global market. The BL breaker family features breakers like the EG that are well suited for OEM designed equipment in both light commercial and industrial applications. This breaker family also includes thermal magnetic breakers, molded case switches and motor circuit protectors.

  • All circuit breakers perform the following functions: sense when an over current occurs, measure the amount of over current act by tripping quickly enough to prevent damage to itself and associated conductors
  • HID lighting - add suffix HID 15 - 30 Amp 1 and 2 pole breakers for high intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker
  • Tungsten lighting - add suffix T 15 - 20 Amp 1 pole breaker used for high wattage, tungsten-lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker
  • Molded case switch - add suffix S 100 Amp 1 pole and 30, 60 and 125 Amp 2 pole breakers for applications that do not require over current protection
  • Switching neutrals - add prefix BG 15 - 30 Amp 2 and 3 pole breakers used where all conductors are required to be disconnected
  • Neutral pole of the circuit breaker does not connect to load center bus one side is wired to neutral and the other side to the device
  • Circuit breaker's compact size saves space and its field-installable accessories allow for last minute changes for all applications

Standard/Approvals: UL Listed, CSA Certified, NOM Certified, HACR Rated

Application: Siemens Load Centers

  • pdfBrochure https://4500cpe.stage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Siemens_B115_Brochure.pdf
  • pdfCatalog https://4500cpe.stage.cimm2.com//ASSETS/DOCUMENTS/ITEMS/EN/Siemens_B115_Catalog.pdf

    • Siemens B240
    • Siemens Series BL Standard Circuit Breaker, Commercial, 120/240 VAC, 40 A, 10 kA Interrupt, ...

    • CPEPN: B240
    • MPN: B240
    • UPC: 783643263574